First Results from New High Magnetic Field Measurements with the MediTPC Prototype
Ralf Diener, Diana Linzmaier

TL;DR
This paper presents initial results from high magnetic field measurements of the MediTPC prototype, focusing on gas contamination effects and resolution performance with new pad planes in the context of the ILD TPC design.
Contribution
It introduces new high magnetic field measurement data for the MediTPC prototype, including effects of oxygen contamination and improved resolution with new pad geometries.
Findings
Oxygen contamination impacts electron signal quality.
Resolution improves with new pad plane design.
High magnetic fields enhance tracking precision.
Abstract
In the ILD concept, a TPC is foreseen as the main tracking device. The MediTPC prototype has been developed at DESY to study the properties of Gas Electron Multipliers (GEMs) and to perform resolution studies. Studies of the influence of oxygen contaminations on the electron signal are presented here. Further, resolution results with new pad planes with 1.27x7.0 sqmm pad pitch and in high magnetic fields are shown.