# X-MAS2: Study Systematics on the ICM Metallicity Measurements

**Authors:** E. Rasia, P. Mazzotta, H. Bourdin, S. Borgani, L. Tornatore, S., Ettori, K. Dolag, L. Moscardini

arXiv: 0707.2614 · 2009-11-13

## TL;DR

This study investigates biases in X-ray measurements of the intracluster medium's metallicity, revealing temperature-dependent systematic errors and emphasizing the impact of spectral resolution and plasma physics on abundance estimates.

## Contribution

The paper introduces a detailed analysis of biases in X-ray metallicity measurements using simulated galaxy clusters, highlighting the effects of plasma physics and spectral resolution.

## Key findings

- Fe is accurately recovered in hot and cold systems but overestimated at intermediate temperatures.
- Oxygen measurements are reliable in cold clusters but overestimated in hot systems.
- Magnesium measurement is challenging, especially in hot clusters, with potential overestimation up to a factor of 4.

## Abstract

(Abridged)The X-ray measurements of the ICM metallicity are becoming more frequent due to the availability of powerful X-ray telescope with excellent spatial and spectral resolutions. The information which can be extracted from the measurements of the alpha-elements, like Oxygen, Magnesium and Silicon with respect to the Iron abundance is extremely important to better understand the stellar formation and its evolutionary history. In this paper we investigate possible source of bias connected to the plasma physics when recovering metal abundances from X-ray spectra. To do this we analyze 6 simulated galaxy clusters processed through the new version of our X-ray MAp Simulator, which allows to create mock XMM-Newton EPIC MOS1 and MOS2 observations. By comparing the spectroscopic results to the input values we find that: i) Fe is recovered with high accuracy for both hot (T>3 keV) and cold (T<2 keV) systems; at intermediate temperatures, however, we find a systematic overestimate which depends on the number counts; ii) O is well recovered in cold clusters, while in hot systems its measure may overestimate by a factor up to 2-3; iii) Being a weak line, the measurement of Mg is always difficult; despite of this, for cold systems (T<2 keV) we do not find any systematic behavior, while for very hot systems (T>5 keV) the spectroscopic measurement may be strongly overestimated up to a factor of 4; iv) Si is well recovered for all the clusters in our sample. We investigate in detail the nature of the systematic effects and biases found. We conclude that they are mainly connected with the multi-temperature nature of the projected observed spectra and to the intrinsic limitation of the XMM-Newton EPIC spectral resolution that does not always allow to disentangle among the emission lines produced by different elements.

## Full text

Tomesphere does not host the full text of arXiv papers. Read it on arXiv: https://arxiv.org/abs/0707.2614

## References

78 references — full list in the complete paper: https://tomesphere.com/paper/0707.2614/full.md

---
Source: https://tomesphere.com/paper/0707.2614