# Sensitivity of the spherical gravitational wave detector MiniGRAIL   operating at 5 K

**Authors:** L. Gottardi, A.de Waard, A.Usenko, G.Frossati, M.Podt, J.Flokstra,, M.Bassan, V.Fafone, Y.Minenkov, A.Rocchi

arXiv: 0705.0122 · 2008-11-26

## TL;DR

This paper reports the initial performance and strain sensitivity measurements of the MiniGRAIL spherical gravitational wave detector operating at 5 K, demonstrating promising sensitivity in the kHz range and potential for future improvements at lower temperatures.

## Contribution

First characterization of MiniGRAIL's performance at 5 K, showing its potential as an ultracryogenic omnidirectional gravitational wave detector in the kHz range.

## Key findings

- Peak strain sensitivity of 1.5×10⁻²⁰ Hz⁻¹/² at 2942.9 Hz
- Achieved sensitivity better than 5×10⁻²⁰ Hz⁻¹/² over 30 Hz bandwidth
- Expected improvement of over an order of magnitude at 50 mK

## Abstract

We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and read out by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output sygnal. We measured a peak strain sensitivity of $1.5\cdot 10^{-20} Hz^{-1/2}$ at 2942.9 Hz. A strain sensitivity of better than $5\cdot 10{-20}Hz{-1/2}$ has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than one order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3kHz range.

## Full text

Tomesphere does not host the full text of arXiv papers. Read it on arXiv: https://arxiv.org/abs/0705.0122

## References

30 references — full list in the complete paper: https://tomesphere.com/paper/0705.0122/full.md

---
Source: https://tomesphere.com/paper/0705.0122